ID #21
HETE J1900.1–2455
short-period LMXB transient · long outburst
NS AMXP
Basic properties
- Position (ICRS) RA [hh:mm:ss.ss], Dec [±dd:mm:ss.s]
- 19:00:09.77 -24:54:04
- Galactic coordinates [deg]
- l = 11.324801°, b = -12.868715°
- Host environment
- Field
- Discovery
- 2005 (Vanderspek2005)
- Distance [kpc]
- 2.9±0.1(H), 3.8(He) (Galloway2020) used for table/plots
Other distance reference(s): Suzuki2007, Galloway2008 - Gaia distance [kpc]
- 3.5+1.7-3.5 (Arnason2021)
- z [kpc]
- -0.646 using preferred distance
- Accretor
- NS
- AMXP
- AMXP (377.29 Hz / 2.65 ms) (Kaaret2006)
- Porb [min]
- 83.2543 0.001 (Kaaret2006)
- Period method
- X-ray pulsation
- Activity
- transient · long outburst
- FX (2–10 keV) [erg cm−2 s−1]
- 3.92E-10 (Papitto2013)
- NH [1022 cm−2]
- 0.105 (Papitto2013)
- Representative magnitude [mag]
- V=18.09±0.03 (Steeghs2005b)
- Proposed companion
- —
Thermonuclear X-ray bursts
- Short-duration bursts
- Reported (Vanderspek2005, Suzuki2007, Papitto2013, Galloway2020)
- Intermediate-duration bursts
- --
- Superbursts
- --
UCXB classification
—Short orbital period
—Low persistent LX
—Low Lopt/LX
—H-poor spectrum
Notes
The source showed intermittent pulsations, detected only sporadically after 2 months of its outburst (e.g., Patruno2012).
Elebert2007 measured a modulation in the R-band light curves that might be due to superhumps.
The source was detected at a net count rate of (2.36 ± 0.03)E-3 count/s during quiescence in 2016 April (Degenaar2017).
QPOs with a single peak at 883 Hz (Kaaret2006) and burst oscillation at ~376 Hz (Watts2009).
Elebert2007 measured a modulation in the R-band light curves that might be due to superhumps.
The source was detected at a net count rate of (2.36 ± 0.03)E-3 count/s during quiescence in 2016 April (Degenaar2017).
QPOs with a single peak at 883 Hz (Kaaret2006) and burst oscillation at ~376 Hz (Watts2009).
Spectral data
- Optical
- Hα, He II λ4686, Bowen blend of N III and C III
Broad He II λ4686 emission line (the spectrum is contaminated by a nearby field star, limiting the detection of Balmer emission components. However, such Balmer emission is at most very weak).
(Elebert2007, Steeghs2005b) - X-ray
- Fe Kα (~6.6 keV), excess at ~1 keV (Fe-Lα and/or Ne-Kα)
(Papitto2013)
Optical/NIR magnitudes
For transient systems, quiescent-counterpart magnitudes are indicated with a q superscript.
R=17.91±0.05,V=18.00±0.04, B=17.92±0.04,
R~18.4,
V=18.09±0.03, R=18.02±0.03, I=17.88±0.02,
J=17.6±0.2
R~18.4,
V=18.09±0.03, R=18.02±0.03, I=17.88±0.02,
J=17.6±0.2
Reference(s): Elebert2007, Fox2005, Steeghs2005b, Steeghs2005